Department of Instrumentation and Control consists of Control System, Process Instrumentation, Sensors and Transducers, Electronic Instrumentation, Analog and Digital Techniques and Project Laboratories.
These laboratories are very well equipped such that every student can perform experiments.
Some of the special instruments available with the department laboratories are Digital Storage Oscilloscope of Make: Yokogawa; Various Level, Pressure and Flow Control Loops etc equipped with different sensors and transmitters and controllers; Mediscope of BPL make; BP measurement machine of conventional and digital types of Diamond make; Audiometer; Optical Fiber Kit of Benchmark make etc.
Some additional facilities are provided for students in project lab like LCD PROJECTOR, OHPs, and COLOUR PRINTER etc.
Academic Year 2009-10 - Term - II |
| S. No. |
NAME OF ITEM |
SPECIFICATION |
QUANTITY |
1 |
Standard Glass Thermometer |
Range of temperature between
0 - 100 0 C and 0 - 50 0 C
least count 0.1 0C and 0.2 0 C .
Used as primary or secondary standard for calibration of working standards |
02 |
2 |
Temperature Controlled Oven |
Temperature Range 0 to 300 ºC. Thermometer, Thermocouple and RTD can be inserted at a time in the oven for measurement, ceramic furnace, on-off temperature controller for set point, Digital Display to indicate the set point and actual process temperature simultaneously, provision for observing mV for thermocouple, Provision for cooling. Accuracy 0.01% of FSD. Resolution 10 C, Display to indicate the existing process variable, Temperature measurement in oven with standard gauge e.g. thermometer |
01 |
3 |
He-Ne Laser diode |
Power-5mW with power supply and stand, wavelength-632.8nm |
01 |
4 |
Abbe refractometer
. |
Refractive index range- 1-1.9
With accuracy 0.0002%,
RI min.division-0.005,
temp. range 0-700C,
fluroscent scale reading |
01 |
5 |
Single beam UV visible |
Deutarium lamp,Tungsten Lamp with digital readout facility, wavelength selection facility and filter selection facility |
01 |
6 |
Spectrophotometer |
20 pin ZIF sockets : min 4 & 40 pin ZIF sockets : min 1
Breadboard : min 1
Supply : Fixed ±5VDC, ±12VDC, ± 15VDC, Variable upto 12VDC
I/P Logic Signals: min 8
Logic Indicators : min 8
Clock & Pulse along with indication of the frequency, Amplitude and Offset :
1 Hz to 1 MHz with fine tuning
Display : 4 Nos of 7 Segment Display
Connection through sturdy 4 mm
Banana sockets & patch cords.
Patch cords : min 30
Patch cord with lung on one side for connection on breadboard : min 30 |
08 |